IRG Documents Database and Compendium


Search and Download IRG Documents:



Between and , sort by


Displaying your search results

Your search resulted in 48 documents. Displaying 25 entries per page.


Detection of feeding behaviour of termites using AE monitoring
1991 - IRG/WP 1514
Using acoustic emission (AE) monitoring, the feeding activity of the termite inhabiting a wood specimen was investigated. The amplitude and the rate of AE from the specimen of Coptotermes formosanus Shiraki was larger than that of Reticulitermes speratus Kolbe. The AE event rate was higher in the specimen with soldiers than without soldiers. The AE event rate decreased according to the resistance ...
Y Imamura, M Tokoro, M Owada, Y Fujii, M Noguchi


Feasibility of termite control using crushed cement-stabilized sludge (Polynite) as a physical barrier and acoustic emission (AE) monitoring
2000 - IRG/WP 00-10381
In Japan, the damages by the subterranean termites (Coptotermes formosanus Shiraki and Reticulitermes speratus Kolbe) are more common. Recently, the more attention is paid to the methods of the termite controls of less- or non-chemical. As one of the non- chemical treatment, physical barrier using particles as basalts 1) , granites, and gravels 2) were investigated in terms of its safety, cost eff...
Y Yanase, M Shibata, Y Fujii, S Okumura, K Iwamoto, T Nogiwa, T Yoshimura, Y Imamura


Feasibility of AE (Acoustic Emission) monitoring for the detection of the activities of wood-destroying insects
1992 - IRG/WP 92-2416
The feasibility of acoustic emission (AE) as a nondestructive testing method for the detection of the wood destroying insects was investigated. AEs were detected from the wood specimens under feeding attack of sugi bark borers or powder-post beetles. However, the feasible monitoring area of an AE sensor is influenced by the attenuation of AE amplitude, so that this could be a problem in the practi...
Y Fujii, Y Imamura, E Shibata, M Noguchi


Detection of Acoustic Emission (AE) generated by termite attack in a wooden house
1999 - IRG/WP 99-20166
Recently, considerable attention has been paid to methods for termite control, which involves few or no chemicals. To reduce the amount of termiticide needed, it is necessary to detect termite attack in wood as early as possible. The feasibility of acoustic emission (AE) monitoring for the nondestructive detection of termite attack has been discussed previously. In this study, we propose some tech...
Y Fujii, Y Yanase, T Yoshimura, Y Imamura, S Okumura, M Kozaki


Detection of termite attack in wood using AE monitoring
1990 - IRG/WP 2355
An acoustic emission (AE) monitoring method for detecting termite activity in wood was applied to lumber of 3 by 3 cm to 10 by 10 cm square, 1 m long. Furthermore, the propagation of AEs due to the feeding activities of termites in the specimens and the locations of AE sources were analyzed. Also discussed was the feasibility of the method applied to posts out in the field of subterranean termites...
Y Fujii, M Owada, M Noguchi, Y Imamura, M Tokoro


A Long-term Observation of Termite Activity in The Nest by Continuous Acoustic Emission (AE) Monitoring
2003 - IRG/WP 03-20280
In order to evaluate the influence of temperature on the termite activity, acoustic emission (AE) monitoring was applied to two nests of Coptotermes formosanus SHIRAKI; a nest in the stem of a standing tree and a nest in the underground of a wooden house, respectively. Temperature change in and around the nests were continuously measured for about one year using thermocouples at four points; the c...
Y Yanase, Y Fujii, S Okumura, T Yoshimura, Y Imamura


Using AE monitoring for detecting economically important species of termites in California
1991 - IRG/WP 2375
Acoustic emission (AE) monitoring was conducted on wooden samples containing three economically important species of termites in California (dampwood termite, Zootermopsis nevadensis, Western drywood termite, Incisitermes minor, and Western subterranean termite, Reticulitermes hesperus). Laboratory AE studies included varying termite species, as well as 7 day studies exploring the periodicity of t...
V R Lewis, R L Lemaster, F C Beall, D L Wood


Detection of Termite Attack to Wood Stakes in a Monitoring Station Using Ceramic Gas Sensors and Acoustic Emission (AE) Sensor
2003 - IRG/WP 03-20271
To evaluate the termite activity in monitoring stations non-destructively, metabolic gas from termites and acoustic emission generated by feeding of termites were measured. Ten cylindrical stations with small wood stakes of Japanese red pine (Pinus densiflora) were buried around a house attacked by Coptotermes formosanus SHIRAKI. A sample air in the station was collected by sucking through a drill...
Y Yanase, Y Fujii, S Okumura, T Yoshimura, Y Imamura, T Maekawa, K Suzuki


Control of termite attack using a trapping method and acoustic emission (AE) monitoring a case study at an electric power plant
1997 - IRG/WP 97-10224
To prevent subterranean termites (Coptotermes formosanus Shiraki and Reticulitermes speratus Kolbe) from invading the buildings of an electric power plant and to control their attack, artificial traps were buried around the buildings. The attack of the termites in and around the traps was monitored by detecting acoustic emissions (AE) generated by the feeding behavior of the workers. The cylindric...
Y Fujii, Y Imamura, E Iwatsubo, S Yamamoto


Detection of termite attack in wood using acoustic emission
1989 - IRG/WP 2331
Acoustic emission (AE) is the elastic wave produced by the strain energy released in the process of fracture of a material and propagates through it. The object of this report is to detect AEs produced by the termite activities and to evaluate the possibility of using an AE monitoring test to nondestructively detect the termite attack in wood. It was revealed that AEs were detected from the specim...
Y Fujii, M Noguchi, Y Imamura, M Tokoro


Use of Acoustic Emission (AE) to detect activity of common European dry-woodboring insects: some practical considerations
2013 - IRG/WP 13-10803
Old house borer (Hylotrupes bajulus), Furniture beetle (Anobium punctatum), and Deathwatch beetle (Xestobium rufovillosum) are common dry-woodboring insects occurring throughout Europe. With the aim to prevent unnecessary use of biocidal products, to protect valuable wooden elements and objects from unwanted influences, and to have a more objective method, SHR has started to study the use of acous...
J G M Creemers


Remote sensing for detection of termite infestations—Proof of Concept
2015 - IRG/WP 15-10846
This paper reports the results of a search to discover the most cost effective and robust method of detecting Reticulitermes flavipes infestations in structural members of remote bridges, homes and other wooden structures and transmitting these results to internet cloud storage thus obviating routine travel to these structures for periodic visual inspections. Duplicate stainless steel tanks were c...
F Green III, R A Arango, C R Boardman, K J Bourne, J C Hermanson, R A Munson


Comparison of AE-apparatus for detection of activity of Old house borer larvae, including reality check
2021 - IRG/WP 21-10981
As part of the German funded project ‘InsectDetect’ comparative measurements were done with three different Acoustic-Emission-(AE)-apparatus on 14 pine beams in order to assess presence of active attack by the Old house borer (Hylotrupes bajulus (L.)). In all beams active attack was measured, though in varying intensity. This was corroborated by completely dissecting 10 of the beams. All thre...
J Creemers, B Plinke, U Noldt


Make ready of a detection system for insect attack by acoustical method
1996 - IRG/WP 96-10183
A contract CRAFT of European research allowed to build a detector prototype able to diagnose on site the presence of Hylotrupes bajulus and termites, even during the first stages of infestation when no sign of activity is visible. Based on non destructive control technics, the device picks up the acoustical waves emitted by the insects in the wood fibers. The amplification and the filtering of the...
M Hyvernaud, F Wiest, M-M Serment, M Angulo, O Winkel


Nondestructive Detection of Biodeterioration in Indonesian Traditional Wooden Construction of “Joglo”
2014 - IRG/WP 14-10834
To decide the repairing and reinforcement method for wooden constructions, it is necessary to get the enough and precise information on the status of the construction beforehand, especially the distribution and the degree of the biodeterioration, such as decay or insect attack (e.g. termite attack). In this study, damage of biodeterioration to teak wood used in Indonesian traditional wooden const...
Y Yanase, T Mori, T Yoshimura, Y P Prihatmaji, J Sulistyo, S Doi


Nondestructive analysis of oviposition of the bamboo powderpost beetle Dinoderus minutus using acoustic emission and X-ray CT
2017 - IRG/WP 17-10889
The bamboo powderpost beetle Dinoderus minutus is a major pest of dry bamboo culms in Japan. In this study, acoustic emission (AE) and X-ray computed tomography (CT) was applied to the nondestructive analysis of the ovipositional behavior of adult D. minutus beetles inside bamboo pieces. Newly mated adult females were individually exposed to oviposition bamboo pieces prepared from culms of Phyllos...
H Watanabe, Y Yanase, Y Fujii


Modélisation sur maquette du rejet accidentel d'un gaz toxique et inflammable dans l'atmosphere - Emission de type "bouffée d'oxyde d'éthyléne [Water model simulation of toxic and flammable gases in the environment on industrial sites - Puff of ethylen oxide]
1990 - IRG/WP 3576
M Milhe


Acoustic communication between Microcerotermes crassus Snyder
1982 - IRG/WP 1158
An unusual acoustic communication within a nest of Microcerotermes crassus SNYDER is reported. The signals produced by the termites are described and possible reasons for this behavior are considered....
U Kny


Rates of emission from CCA-treated wood in the marine environment: measurement, modelling and requirements for further research
2001 - IRG/WP 01-50166-12
Accurate estimates of rates of emission of leachate from preservative treated wood are crucial for realistic predictions of the environmental impact of its use in maritime construction. Estimates are available for some commonly used preservatives, but these vary widely. Though variable, these measurements suggest that emission generally decreases exponentially with time. Part of the variation is d...
S M Cragg, C J Brown, R A Albuquerque, R A Eaton


Methane emission by termites, Coptotermes formosanus Shiraki
1995 - IRG/WP 95-10099
Association of methanogenic bacteria only with the smallest-sized symbiotic protozoa Spirotrichonympha leidyi Koidzumi was evidenced by epifluorescence microscopic observations. Workers, which were collected from a laboratory colony and placed in a test container with water supply emitted methane at a relatively constant rate with a peak of 0.76 nmol/termite/hr within the first 72 hrs after the in...
K Tsunoda, W Ohmura, M Tokoro, T Yoshimura


A review of environmental emissions from building and construction materials in comparison with preserved wood
2005 - IRG/WP 05-50224-11
A review of the public domain literature concerning emissions to the environment from materials which are used in the construction of buildings (e.g. Concrete, Asphalt, Galvanised Steel), in comparison with preserved wood, and a review of the approaches taken by the construction sector in assessing the risk from environmental emissions, in comparison with the approaches taken by the wood preservat...
E F Baines


Measurement of VOC emissions from curative treated wood: A new emission test chamber
2001 - IRG/WP 01-50166-13
A poor indoor air quality (IAQ) is now recognized as a potential factor affecting occupants health. There are three basic strategies to improve IAQ: source control, improvement of the ventilation and use of air cleaners. Usually, the most efficient way to improve IAQ is to eliminate the different pollutant sources or to reduce their emissions. In order to precisely measure emissions from building ...
F Maupetit, O Ramalho, C Yrieix


How to determine what is a realistic emission from treated wood - basic reflections
1998 - IRG/WP 98-50105
Emissions from treated wood occur by evaporation and by leaching. Up to date by far more experience exists on leaching tests than on evaporation test. The methods applied will be of interest to give answers to the questions about the quantity of possible emissions. Standardisation on leaching started very early. One of the first attempts to quantify the effect of leaching on the remaining efficacy...
H Willeitner, R-D Peek


Effect of leaching temperature and water acidity on the loss of metal elements from CCA treated timber in aquatic conditions. Part 2: Semi-industrial investigation
1995 - IRG/WP 95-50040-13
In continuation of previous leaching research on the quantification and modelling of metal elements released from CCA treated timber, a series of experiments has been carried out dealing with the influence of temperature and pH of the relative aquatic environment. The leaching method used is the Dutch prestandard for building materials, a long term static leaching test simulating practical bank-sh...
G M F Van Eetvelde, W J Homan, H Militz, M Stevens


Emission of trimethyl borate and methanol from radiata pine (Pinus radiata D. Don)
1995 - IRG/WP 95-30088
Sawn and kiln dried radiata pine conditioned to 3, 6, and 12% moisture content was treated with trimethyl borate (TMB). The treated wood samples were placed in mini-desiccators maintained at 20 or 40°C. The air space within the mini-desiccator was analysed for TMB and methanol. An initial period of emission of TMB and methanol was observed. This was followed by a period of gradual dissipation of ...
F J Romero, P Vinden, J A Drysdale


Next Page